Construction
• Cabinet is 5 mm steel sheet, mounted on a stand fabricated from 64 x 64 x 2.6mmR.H.S. and finished in Hammerfin Blue enamel.
Refractory Lining
• Hot face of 70% alumina fire-brick backed with insulating fire-brick.
Internal Dimensions
• 300mm high x 480mm wide x 560mm deep.
Burner Equipment and Ratings
• LPG – 1 x 40mm long pattern inspirator with flame retention nozzle. 270 mj/hr @ 140 kpa.
• Natural Gas – Furnace Industries NG2 Burner package. 270mj/hr @ 3 kpa.
• Distillate – Furnace Industries Oil Burner Package. 270mj/hr.
Flame Supervision
• LPG – Landis & Gyr LGB 41 flame controller and U.V. cell
• Nat. Gas & Distillate – Landis & Gyr LFL1.635.
Temperature Control
Electronic, Automatic control 1200°C, type “K” Thermocouple
Electrical Requirements
• The furnace is fitted with a 10 AMP single phase cord and plug top. Electrical load: 5Amps.
Door Operation
• Pneumatic rising. Operated by foot control.