Construction
• Cabinet is 5 mm steel sheet, mounted on a stand fabricated from 64 x 64 x 2.6mm R.H.S.and finished in Hammerfin Blue enamel.
Refractory Lining
• Hot face of 70% alumina fire-brick backed with insulating fire-brick.
Internal Dimensions
• 400mm high x 1200mm wide x 680mm deep.
Burner Equipment and Ratings
• LPG – 2 x 40mm long pattern inspirator with flame retention nozzle. 540 mj/hr @ 140 kpa.
• Natural Gas - Furnace Industries NG2 Burner package. 540mj/hr
• Distillate - Furnace Industries OIL2 Burner package. 540mj/hr
Flame Supervision
• LPG - Landis & Gyr LGB 41 flame controller and U.V. cell
• Nat. Gas & Distillate - Landis & Gyr LFL1.635 and LFE10 Flame Controller.
Temperature Control
Electronic, Automatic control 1200°C, type “K” Thermocouple
Electrical Requirements
• The furnace is fitted with a 10 AMP single phase cord and plug top. Electrical load: 5 Amps.
Door Operation
• Pneumatic rising. Operated by foot control.